High-Sensitivity Field Nucleic Acid Test Kit

Target: Bactrocera dorsalis.

IFU sample types: insect specimens; follow the specimen preparation in the IFU.

GeneVide field nucleic acid kit packaging example
Representative GeneVide kit packaging. Target-specific reagents and contents are defined below.

Product overview

GeneVide Bactrocera dorsalis Oriental Fruit Fly On-Site Test Kit · GV-PLT-BD

This kit amplifies nucleic acid sequences specific to Oriental Fruit Fly and uses directional signal amplification technology to achieve high-sensitivity detection of the target nucleic acid.

Kit and instrument are separate. This reagent kit is used with compatible GeneVide field-testing equipment. View the EmDEA V3 platform or ask the product team to confirm your setup.

Package specification in the IFU

16 tests/box

The IFU describes the individual box. Confirm the current sales-pack quantity, price, shipping, and availability on the linked eBay listing before purchasing; an order may contain multiple boxes.

Test principle

This kit amplifies nucleic acid sequences specific to Oriental Fruit Fly and uses directional signal amplification technology to achieve high-sensitivity detection of the target nucleic acid.

Kit components

Table 1. Main components

No.ComponentMain ingredientsSpecificationQty.
1Oriental Fruit Fly enzyme pelletPrimers, probe, endonuclease, deoxyribonucleoside triphosphates, polymerase16 tests/pack1
2Oriental Fruit Fly positive controlTarget plasmid containing the target fragment280 μL/tube1
3Negative controlNuclease-free water280 μL/tube1

Storage and shelf life

Store the test kit at 2–8°C. Shelf life: 12 months.

Workflow and result interpretation

These instructions are specific to Oriental Fruit Fly. Follow the full IFU, including controls and precautions. Reaction thresholds are not total sample-to-result times.

Test Procedure
  1. Remove and cut off the required number of enzyme-pellet tubes. Along the wall of separate tubes, add 50 μL of negative control, nucleic acid solution for testing, and positive control, respectively. After all solutions have been added, visually confirm that the solution has completely dissolved the enzyme pellet.
  2. Close the tube caps. Hold both ends of each tube between the thumb and index finger, mix up and down for 10 cycles, and flick gently 3 times to collect the liquid at the bottom. Visually confirm that the liquid level is uniform and no bubbles remain at the bottom; then place the tubes in the palm-sized fluorescence detector for testing.

Note: Manual mixing is a critical step. Before starting the test, make sure the enzyme-pellet tube caps and the lid of the palm-sized fluorescence detector are closed tightly.

Result Interpretation

At the end of the test program, the palm-sized fluorescence detector automatically analyzes and determines the result.

Table 2. Result interpretation for the palm-sized fluorescence detector

AssessmentTT displayDisplayed result
Negative control—NC
Positive controlTT ≤ 10PC
Positive sampleTT ≤ 20Positive
Negative sample—Negative
Equipment and Consumables Required but Not Provided
  1. Personal protective equipment (disposable laboratory gloves, laboratory coat, protective eyewear, etc.).
  2. Timer.
  3. Liquid-waste container.
Precautions
  1. Do not use expired reagents.
  2. Perform the entire procedure in a nuclease-free environment.
  3. Wear powder-free gloves when handling reagents and nucleic acids.
  4. To avoid cross-contamination, filtered pipette tips are recommended.
  5. All sample tubes, centrifuge tubes, tips, reagents, and test tubes are single-use.
  6. Do not mix reagents from different product lots.

Instructions for Use (IFU)

IFU revision: August 13, 2026. English translation based on the corresponding Chinese instruction sheet.

Download English IFUChinese IFU (PDF)

Can I use a different sample type?

The stated sample types are insect specimens; follow the specimen preparation in the IFU. Contact the product team before using an unlisted sample or modifying the procedure.

Does this kit include the detector?

No. The portable platform is listed separately. Consult the components table and IFU for what is supplied with the reagent kit.

Selection and purchasing questions

Is the oriental fruit fly kit the Mediterranean fruit fly kit?

No. This kit names Bactrocera dorsalis. The Mediterranean fruit fly product names Ceratitis capitata; select by the full scientific name when common names are ambiguous.

What should I include in a Bactrocera dorsalis Detection Kit inquiry?

Include SKU GV-PLT-BD, your actual specimen (the IFU lists insect specimens; follow the specimen preparation in the IFU), testing volume, existing equipment and destination. Confirm the sales-pack quantity separately from the individual-box specification in the IFU.